Files
hyperguild/ingestion
mathiasandClaude Opus 5.5 4ba9d20b4e
CI / Lint / Test / Vet (pull_request) Successful in 41s
CI / Mirror to GitHub (pull_request) Skipped
fix(ingestion): tripwire alerts survive outages; drop only permanent rejections
PR #160 round 2: dropping a message after 5 failures could not tell a
poison message from an ntfy outage. A 15-minute outage dropped the only
incident with nothing reported, and drops were not counted (74 of 300
removals were neither delivered nor counted).

- audit.NtfyNotifier returns *RejectedError for non-2xx; Permanent() is
  true for 4xx other than 429.
- The tripwire queue drops a message only on a permanent rejection and
  counts it; every other failure is an outage and is retried, however
  long. Each flush tries every queued message, so an undeliverable one
  cannot block the rest.
- Overflow and drops go into one counter, sent as a summary retried
  every tick and never dropped. Every removal is delivered or counted.

Tests (red first): an outage of ~100 ticks still delivers the only
incident; delivered + counted equals the number of removals; a
permanently rejected message is dropped and counted. The short-outage
test is renamed to say it is short. The Watch doc no longer claims
'loses none' unconditionally.

Refs #157

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-03 18:30:46 +02:00
..